Lite-parity audit, sync-progress semantics (state/presentation only — no send/sync backend call changed):
- A scan failure set scan->failed + lite_error, but no UI read lite_error, so the user saw "Syncing 99.9%"
forever. The status bar now shows the error text on a lite scan/server failure.
- After the initial catch-up, a server loss on the cheap probe path (ProbeFailed) left the last "Synced"
model on screen. The worker now re-publishes that model demoted (not complete, reason "server unreachable").
- refreshModelImpl's height-read "synced" override no longer fires while syncstatus says the backend is
still scanning or is indeterminate, and a server-bound read failure in a full cycle demotes to not-synced.
- The syncstatus parser no longer treats a missing/unrecognised "syncing" field as fully synced: it reports
an explicit "indeterminate" (not complete). Explicit "false" stays caught-up; the fake backend's
syncing:true 1000/1000 behaviour is unchanged.
Tests: parser cases for missing/odd/idle "syncing" (testLiteSyncStatus*).
Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>